First name
Brigitte
Last name
Lemyre

Title

Nasal Intermittent Positive Pressure Ventilation Versus Nasal Continuous Positive Airway Pressure to Prevent Primary Noninvasive Ventilation Failure in Extremely Low Birthweight Infants.

Year of Publication

2019

Date Published

2019 Oct 08

ISSN Number

1097-6833

Abstract

<p>Reducing the risk of primary noninvasive ventilation failure in extremely low birthweight infants is linked to reducing bronchopulmonary dysplasia. In a secondary analysis of randomized data, we identified that failure rates and time to failure were similar for nasal intermittent positive pressure ventilation vs nasal continuous positive airway pressure.</p>

DOI

10.1016/j.jpeds.2019.08.064

Alternate Title

J. Pediatr.

PMID

31604630

Title

Variation in Positive End-Expiratory Pressure Levels for Mechanically Ventilated Extremely Low Birth Weight Infants.

Year of Publication

2018

Number of Pages

28-33.e5.

Date Published

2018 Mar

ISSN Number

1097-6833

Abstract

<p><strong>OBJECTIVE: </strong>To test the hypothesis that significant positive end-expiratory pressure (PEEP) level variation exists between neonatal centers.</p>

<p><strong>STUDY DESIGN: </strong>We performed a secondary analysis cohort study of the Nasal Intermittent Positive-Pressure Ventilation trial. Our study population was extremely low birth weight infants requiring mechanical ventilation within 28 days of life. The exposure was neonatal center; 34 international centers participated in the trial. Subjects from centers with fewer than 5 eligible cases were excluded. The main outcome was the maximal PEEP level used during the first course of mechanical ventilation. Infant characteristics judged a priori to directly influence clinical PEEP level selection and all characteristics associated with PEEP at P &lt;.05 in bivariable analyses were included with and without center in multivariable linear regression models. Variation in PEEP level use between centers following adjustment for infant characteristics was assessed.</p>

<p><strong>RESULTS: </strong>A total of 278 extremely low birth weight infants from 17 centers were included. Maximal PEEP ranged from 3 to 9 cm H2O, mean = 5.7 (SD = 0.9). Significant variation between centers remained despite adjustment for infant characteristics (P &lt; .0001). Further, center alone explained a greater proportion of the PEEP level variation than all infant characteristics combined.</p>

<p><strong>CONCLUSIONS: </strong>Marked variation in PEEP levels for extremely low birth weight infants exists between neonatal centers. Research providing evidence-based guidance for this important aspect of respiratory care in preterm infants at high risk of lung injury is needed.</p>

<p><strong>TRIAL REGISTRATION: </strong>ClinicalTrials.govNCT00433212.</p>

DOI

10.1016/j.jpeds.2017.10.065

Alternate Title

J. Pediatr.

PMID

29275926

WATCH THIS PAGE