First name
James
Middle name
K
Last name
Kirklin

Title

Sixth Annual Pediatric Interagency Registry for Mechanical Circulatory Support (Pedimacs) Report: The Society Of Thoracic Surgeons Pedimacs Annual Report.

Year of Publication

2023

Number of Pages

1098-1108

Date Published

05/2023

ISSN Number

1552-6259

Abstract

BACKGROUND: The Pediatric Interagency Registry for Mechanical Circulatory Support (Pedimacs), supported by The Society of Thoracic Surgeons, provides detailed information on pediatric patients supported with ventricular assist devices (VADs).

METHODS: From September 19, 2012, to December 31, 2021, there were 1355 devices in 1109 patients (<19 years) from 42 North American Hospitals.

RESULTS: Cardiomyopathy was the most common underlying cause (59%), followed by congenital heart disease (25%) and myocarditis (9%). Regarding device type, implantable continuous (IC) VADs were most common at 40%, followed by paracorporeal pulsatile (PP; 28%) and paracorporeal continuous (PC; 26%). Baseline demographics differed, with the PC cohort being younger, smaller, more complex (ie, congenital heart disease), and sicker at implantation (P < .0001). At 6 months after VAD implantation, a favorable outcome (transplantation, recovery, or alive on device) was achieved in 84% of patients, which was greatest among those on IC VADs (92%) and least for PC VADs (69%). Adverse events were not uncommon, with nongastrointestinal bleeding (incidence of 14%) and neurologic dysfunction (11% [stroke, 4%]), within 2 weeks after implantation being the most prevalent. Stroke and bleeding had negative impacts on overall survival (P = .002 and P < .001, respectively).

CONCLUSIONS: This Sixth Pedimacs Report demonstrates the continued evolution of the pediatric field. The complexity of cardiac physiologies and anatomic constraint mandates the need for multiple types of devices used (PC, PP, IC). Detailed analyses of each device type in this report provide valuable information to further advance the care of this challenging and vulnerable population.

DOI

10.1016/j.athoracsur.2022.10.042

Alternate Title

Ann Thorac Surg

PMID

36402175
Featured Publication
No

Title

Fifth Annual Pediatric Interagency Registry for Mechanical Circulatory Support (Pedimacs) Report.

Year of Publication

2021

Date Published

2021 Oct 11

ISSN Number

1552-6259

Abstract

<p><strong>BACKGROUND: </strong>The Pediatric Interagency Registry for Mechanical Circulatory Support (Pedimacs) provides detailed information on pediatric patients supported with ventricular assist devices (VADs).</p>

<p><strong>METHODS: </strong>From September 19, 2012 to December 31, 2020 there were 1,229 devices in 1,011 patients reported to the registry from 47 North American Hospitals in patients under 19 years of age.</p>

<p><strong>RESULTS: </strong>Cardiomyopathy was the most common underlying etiology (58%), followed by congenital heart disease (CHD) (25%) and myocarditis (10%). The most common devices implanted were implantable continuous (IC) (n=419, 41%), followed by paracorporeal pulsatile (PP) (n=269, 27%), paracorporeal continuous (PC) (n=263, 26%), and percutaneous (n=53, 5%). Overall, at six months after VAD implantation, 83% had a positive outcome (transplant, explant, or alive on device). The freedom from stroke was highest in IC VADs (93% at 3-months), compared to PP VADs (84% at 3-months) and with PC VADs (75% at 3-months. There were differences in survival by device type with patients on IC VADs having the best overall survival and those on PC having the lowest overall survival, though the patient populations being supported by each VAD type differed significantly from each other.</p>

<p><strong>CONCLUSIONS: </strong>This Fifth Pedimacs Report demonstrates the continued robust growth of VADs in the pediatric community, now with over 1000 patients reported to the registry. The multiple available device types (PC, PP, IC) serve different populations with different pre-VAD risk profiles, which may account for differences in survival and AE between device types.</p>

DOI

10.1016/j.athoracsur.2021.10.001

Alternate Title

Ann Thorac Surg

PMID

34648810

Title

Resource utilization in children with paracorporeal continuous-flow ventricular assist devices.

Year of Publication

2021

Date Published

2021 Feb 22

ISSN Number

1557-3117

Abstract

<p><strong>BACKGROUND: </strong>Paracorporeal continuous-flow ventricular assist devices (PCF VAD) are increasingly used in pediatrics, yet PCF VAD resource utilization has not been reported to date.</p>

<p><strong>METHODS: </strong>Pediatric Interagency Registry for Mechanically Assisted Circulatory Support (PediMACS), a national registry of VADs in children, and Pediatric Health Information System (PHIS), an administrative database of children's hospitals, were merged to assess VAD implants from 19 centers between 2012 and 2016. Resource utilization, including hospital and intensive care unit length of stay (LOS), and costs are analyzed for PCF VAD, durable VAD (DVAD), and combined PCF-DVAD support.</p>

<p><strong>RESULTS: </strong>Of 177 children (20% PCF VAD, 14% PCF-DVAD, 66% DVAD), those with PCF VAD or PCF-DVAD are younger (median age 4 [IQR 0-10] years and 3 [IQR 0-9] years, respectively) and more often have congenital heart disease (44%; 28%, respectively) compared to DVAD (11 [IQR 3-17] years; 14% CHD); p &lt; 0.01 for both. Median post-VAD LOS is prolonged ranging from 43 (IQR 15-82) days in PCF VAD to 72 (IQR 55-107) days in PCF-DVAD, with significant hospitalization costs (PCF VAD $450,000 [IQR $210,000-$780,000]; PCF-DVAD $770,000 [IQR $510,000-$1,000,000]). After adjusting for patient-level factors, greater post-VAD hospital costs are associated with LOS, ECMO pre-VAD, greater chronic complex conditions, and major adverse events (p &lt; 0.05 for all). VAD strategy and underlying cardiac disease are not associated with LOS or overall costs, although PCF VAD is associated with higher daily-level costs driven by increased pharmacy, laboratory, imaging, and clinical services costs.</p>

<p><strong>CONCLUSION: </strong>Pediatric PCF VAD resource utilization is staggeringly high with costs primarily driven by pre-implantation patient illness, hospital LOS, and clinical care costs.</p>

DOI

10.1016/j.healun.2021.02.011

Alternate Title

J Heart Lung Transplant

PMID

33744087

Title

Fourth Annual Pediatric Interagency Registry for Mechanical Circulatory Support (Pedimacs) Report.

Year of Publication

2020

Date Published

2020 Oct 08

ISSN Number

1552-6259

Abstract

<p><strong>BACKGROUND: </strong>Pedimacs, an originally NIH-sponsored U.S. database, provides a platform to understand the population of children supported with VADs during this time of increasing numbers, new devices, expanding indications, and improved outcomes.</p>

<p><strong>METHODS: </strong>Between 9/19/12-12/31/19, 44 hospitals implanted 1031 devices in 856 patients under 19 years-of-age.</p>

<p><strong>RESULTS: </strong>Overall, diagnosis was cardiomyopathy in 497(58%), congenital heart disease(CHD) in 216(25%), myocarditis in 85(10%), and other in 58(7%). Positive outcome (alive on device or bridge to transplantation/recovery) occurred in 82% at 6-months. The patient cohort for implantable continuous flow(IC) pumps (n=365)[age:13.2+/-3.9yrs., 18% INTERMACS profile-1, 23% intubated at implant, 16% with CHD] was significantly different from the paracorporeal continuous flow(PC) pump cohort (n=212)[age:3.6+/-4.9yrs, 46% INTERMACS profile-1, 81% intubated, 42% CHD] and the paracorporeal pulsatile(PP) pump cohort (n=230)[age:2.7 +/-3.5yrs, 31% INTERMACS profile-1, 76% intubated, 26% CHD]. Consistent with their cohort composition, positive outcomes at 6 months based on device type were IC-92%, PC-68%, and PP-81%. The incidence of cerebrovascular accidents(CVA) in the IC, PC, and PP cohorts is 7%, 14% and 15%, respectively.</p>

<p><strong>CONCLUSIONS: </strong>IC VADs, the most common VAD-type placed in children, are associated with improved outcomes compared to PP/PC devices, though PP/PC devices are limited to supporting our most challenging patients. Noteworthy, the incidence of CVA for pediatric VADs has significantly decreased and is now 11% overall. This report demonstrates again that although often attributed to age, size, or device type, much of the burden in mortality and adverse events is correlated to the patient's overall state at VAD implantation.</p>

DOI

10.1016/j.athoracsur.2020.09.003

Alternate Title

Ann Thorac Surg

PMID

33039359

Title

Third Annual Pediatric Interagency Registry for Mechanical Circulatory Support (Pedimacs) Report: Pre-Implant Characteristics and Outcomes.

Year of Publication

2019

Date Published

2019 Feb 25

ISSN Number

1552-6259

Abstract

<p><strong>BACKGROUND: </strong>The influence of ventricular assist device (VAD) use in the care of children with end-stage heart failure is growing rapidly through increasing numbers, new devices, expanding indications, and improving outcomes. Pedimacs, a NIH-sponsored U.S. database, provides a platform to understand this emerging population.</p>

<p><strong>METHODS: </strong>Between 9/19/12-12/31/17, 30 hospitals implanted 508 devices in 423 patients under 19 years-of-age. This past year was one of evolution for the Database as its management was transitioned to the Society of Thoracic Surgery, therefore data from institutions not under contract by August 1 2018 was not included in this report.</p>

<p><strong>RESULTS: </strong>Of the 423 patients, the diagnosis was cardiomyopathy in 261 (62%), myocarditis in 48 (11%), other in 28 (7%) and congenital heart disease in 86 (20%) with 52 of these patients having single ventricle physiology. The two most common support strategies included LVAD-342 (81%) and BiVAD-64 (15%). Positive Outcome (alive on device or bridge to transplantation/recovery) was 80% at 6-months (overall mortality of 20%). The patient cohort for implantable continuous flow (IC) pumps (n=197) [age at implant 13.4+/-3.8yrs., 19% INTERMACS profile-1, 21% intubated at implant and 12% with CHD] was significantly different from the paracorporeal continuous flow (PC) pump cohort (n=79) [age 3.9+/-5.2yrs, 49% INTERMACS profile-1, 86% intubated at implant, and 38% with CHD] and the paracorporeal pulsatile (PP) pump cohort (n=121) [age 3.3+/-3.9yrs, 41% INTERMACS profile-1, 77 % intubated at implant, and 21% with CHD]. Consistent with their cohort composition, device type positive outcomes at 6 months were PC-63%, PP-77% and IC-92%. Using Parametric Hazard Modeling, an early hazard for death was associated with INTERMACS profile-1, BiVAD, percutaneous devices, PC devices, small volume institutions, low age and low weight, while a constant hazard was associated with intubation and liver dysfunction at time of implant.</p>

<p><strong>CONCLUSIONS: </strong>IC VADs are the most common VAD type placed in children. The positive outcomes for the IC VADs are &gt;90% at 6 months, which may represent our field's maturation in both patient selection and timing of implantation. Currently the PP/PC devices are limited to supporting our most challenging patients, those less than 20kg, and those with CHD. The introduction of new devices and our communities' commitment to shared learning and improvement will lead to more pediatric lives saved by VAD support, and will also focus on improving the quality of life of children supported with VADs.</p>

DOI

10.1016/j.athoracsur.2019.01.038

Alternate Title

Ann. Thorac. Surg.

PMID

30817920

Title

Resource Utilization in Pediatric Patients Supported With Ventricular Assist Devices in the United States: A Multicenter Study From the Pediatric Interagency Registry for Mechanically Assisted Circulatory Support and the PHIS

Year of Publication

2018

Date Published

2018 Jun 01

ISSN Number

2047-9980

Abstract

<p><strong>BACKGROUND: </strong>Few data exist on resource utilization with pediatric ventricular assist devices (VADs). We tested the hypothesis that device type and adverse events are associated with increased resource utilization in pediatric patients supported with VADs.</p>

<p><strong>METHODS AND RESULTS: </strong>The Pediatric Interagency Registry for Mechanically Assisted Circulatory Support, a national registry of VADs in patients &lt;19&nbsp;years old, and the Pediatric Health Information System, an administrative database, were merged. Univariate analysis was performed assessing the association of all factors with the total cost and length of stay first. Significant variables (&lt;0.05) were subjected to multivariable analysis. The study included 142 patients from 19 centers with VAD implants from October 2012 to June 2016. The median age was 9&nbsp;years (interquartile range [IQR] 2-15), 84 (59%) supported with a continuous-flow VAD. Overall median hospital costs were $750&nbsp;000 (IQR $539&nbsp;000 to $1&nbsp;100&nbsp;000) with a median hospital length of stay of 81&nbsp;days (IQR 54-128). On multivariable analysis, device type and postoperative complications were not associated with resource utilization. Factors associated with increased costs included patient age, lower-volume VAD center, being intubated, being on extracorporeal membrane oxygenation, number of complex chronic medical conditions, and length of stay. Among continuous-flow VAD patients, discharge to home before transplant versus remaining hospitalized was associated with lower hospital costs (median $600&nbsp;000 [IQR $400&nbsp;000 to $820&nbsp;000] versus median $680&nbsp;000 [IQR $500&nbsp;000 to $970&nbsp;000], =0.03).</p>

<p><strong>CONCLUSION: </strong>VADs in pediatric patients are associated with high resource utilization. Increased resource utilization was associated with lower-volume VAD centers, disease severity at VAD implantation, and the presence of complex chronic medical conditions. Further study is needed to develop cost-effective strategies in this complex population.</p>

DOI

10.1161/JAHA.117.008380

Alternate Title

J Am Heart Assoc

PMID

29858364

Title

Outcomes of children implanted with ventricular assist devices in the United States: First analysis of the Pediatric Interagency Registry for Mechanical Circulatory Support (PediMACS).

Year of Publication

2016

Number of Pages

578-84

Date Published

2016 May

ISSN Number

1557-3117

Abstract

<p><strong>BACKGROUND: </strong>Use of mechanical circulatory support in children has increased as more options have become available. A national account of the use of mechanical support in children and adolescents is essential to understanding outcomes, refining patient selection and improving quality of care.</p>

<p><strong>METHODS: </strong>The Pediatric Interagency Registry for Mechanical Circulatory Support (PediMACS) is a National Heart, Lung, and Blood Institute-supported nationwide registry for temporary and durable ventricular assist device (VAD) use in patients &lt;19 years of age. Between the launch in September 2012 and June 2015, 37 hospitals in the USA have enrolled patients. This first report of data from PediMACS analyzed pre-implant patient characteristics, survival using competing outcomes, and adverse events.</p>

<p><strong>RESULTS: </strong>Two hundred pediatric patients underwent 222 durable VAD implants. Patients' characteristics and outcomes of children supported with a temporary device (n = 41) were not analyzed in this report. The etiology of heart disease included 146 (73%) patients with cardiomyopathy and 35 (18%) with congenital heart disease. Thirty patients (15%) transitioned from extracorporeal membrane oxygenation (ECMO) and 76 (38%) had previous cardiac surgery. Most patients were Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) Level 1 (27%) or Level 2 (56%) at implant, with 13% at Level 3. Of the 200 patients supported with a durable device, 91 (46%) were supported with a pulsatile-flow device and 109 (55%) with a continuous-flow (CF) device. Patient age at first implant included 30 patients (15%) &lt;1 year of age, 37 (19%) 1 to 5 years, 32 (16%) 6 to 10 years and 101 (51%) 10 to 18 years. Patients were supported with left ventricular assist device alone in 161 (81%), biventricular ventricular assist device in 29 (15%), right ventricular assist device in 4 (2.0%) and total artificial heart in 6 (3%), together comprising 783 months of follow-up. The 200 patients receiving primary durable devices had an actuarial survival of 81% at 6 months. Competing risk analysis at 6 months revealed that 58% of patients had been transplanted, 28% were alive on support, 14% had died and 0.6% recovered. In the overall cohort, there were 28 deaths. Reported serious adverse events included infection (n = 78), bleeding (n = 68), device malfunction (n = 79) and neurologic dysfunction (n = 52).</p>

<p><strong>CONCLUSIONS: </strong>PediMACS constitutes the largest single data repository with detailed information of pediatric patients implanted with VADs. The first PediMACS report reveals favorable outcomes despite the varying patient characteristics and pump types. However, the rate of adverse events remains high. With further data collection, analysis of patient risk factors critical to improving outcomes will be possible.</p>

DOI

10.1016/j.healun.2016.01.1227

Alternate Title

J. Heart Lung Transplant.

PMID

27009673

Title

Outcomes of pediatric patients supported with continuous-flow ventricular assist devices: A report from the Pediatric Interagency Registry for Mechanical Circulatory Support (PediMACS).

Year of Publication

2016

Number of Pages

585-90

Date Published

2016 May

ISSN Number

1557-3117

Abstract

<p><strong>BACKGROUND: </strong>Continuous-flow (CF) ventricular assist devices (VADs) have largely replaced pulsatile-flow VADs in adult patients. However, there are few data on CF VADs among pediatric patients. In this study we aimed to describe the overall use, patients' characteristics and outcomes of CF VADs in this population.</p>

<p><strong>METHODS: </strong>The Pediatric Interagency Registry for Mechanical Circulatory Support (PediMACS) is a national registry for U.S. Food and Drug Adminstration (FDA)-approved VADs in patients &lt;19 years of age. Patients undergoing placement of durable CF VADs between September 2012 and June 2015 were included and outcomes were compared with those of adults from the Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS).</p>

<p><strong>RESULTS: </strong>CF VADs were implanted in 109 patients at 35 hospitals. The median age at implantation was 15 years (2.8 to 18.9 years) and median weight was 62 kg (range 16 to 141 kg). The underlying disease was cardiomyopathy in 89 (82%) patients. The INTERMACS level at time of implant was Level 1 in 20 (19%), Level 2 in 64 (61%) and Levels 3 to 7 in 21 (20%) patients. Most were implanted as LVADs (n = 102, 94%). Median duration of support was 2.3 months (range &lt;1 day to 28 months). Serious adverse event rates were low, including neurologic dysfunction (early event rate 4.1 per 100 patient-months with 2 late events). Competing outcomes analysis at 6 months post-implant indicated 61% transplanted, 31% alive with device in place and 8% death before transplant. These outcomes compared favorably with the 3,894 adults supported with CF VADs as a bridge to transplant.</p>

<p><strong>CONCLUSIONS: </strong>CF VADs are commonly utilized in older children and adolescents, with excellent survival rates. Further study is needed to understand impact of patient and device characteristics on outcomes in pediatric patients.</p>

DOI

10.1016/j.healun.2016.01.1228

Alternate Title

J. Heart Lung Transplant.

PMID

27056612

Title

Second annual Pediatric Interagency Registry for Mechanical Circulatory Support (Pedimacs) report: Pre-implant characteristics and outcomes.

Year of Publication

2018

Number of Pages

38-45

Date Published

2018 Jan

ISSN Number

1557-3117

Abstract

<p><strong>BACKGROUND: </strong>Expanded use of pediatric ventricular assist devices (VADs) has decreased mortality in children awaiting heart transplantation. Pediatric Interagency Registry for Mechanical Circulatory Support (Pedimacs), a National Heart, Lung, and Blood Institute-sponsored North American database, provides a platform to understand this emerging population.</p>

<p><strong>METHODS: </strong>Between September 2012 and September 2016, patients aged younger than 19 years who underwent VAD implantation were enrolled in Pedimacs. FDA approved durable devices as well as temporary support devices were included. The second annual report updates the current Pedimacs data. Patients implanted with temporary devices are included in Pedimacs and this analysis includes this group of paracorporeal continuous flow VADs.</p>

<p><strong>RESULTS: </strong>Over the 4 years, 42 hospitals implanted 432 devices in 364 patients less than 19 yrs of age. Diagnoses included cardiomyopathy in 223 (61%), myocarditis in 41 (11%), and congenital heart disease in 77 (21%), of which 48 had single-ventricle physiology. At implant, 87% were at Intermacs patient profile 1 or 2. The age distribution of children (59% male) supported on VAD included 69 (19%) aged younger than 1 year, 66 (18%) aged 1 to 6 years, 56 (15%) aged 6 to 10 years, and 173 (48%) aged 11 to 19 years. Median follow-up was 2.2 months (range, 1 day to 41.5 months). Median (interquartile) age at implant was 1.7 (0.3-10.0) years for paracorporeal continuous-flow pumps (n = 60), 1.7 (0.4-5.3) years for paracorporeal pulsatile pumps (n = 105), and 15.0 (11.3-16.9) years for implantable continuous-flow pumps (n = 174). Support strategies included LVAD in 293 (80%), biventricular device in 55 (15%), and total artificial heart in 8 (2%). Nearly 50% of patients underwent transplantation within 6 months, with overall mortality of 19%. Adverse event burden continues to be high.</p>

<p><strong>CONCLUSIONS: </strong>Pedimacs constitutes the largest longitudinal pediatric VAD registry. Preimplant data across centers will be helpful at creating shared protocols with which to improve outcomes. Adverse events continue to be the major challenge, especially among the young critically ill children with complex congenital disease.</p>

DOI

10.1016/j.healun.2017.06.017

PMID

28965736