First name
Ryan
Middle name
S
Last name
Cantor

Title

Resource utilization in children with paracorporeal continuous-flow ventricular assist devices.

Year of Publication

2021

Date Published

2021 Feb 22

ISSN Number

1557-3117

Abstract

<p><strong>BACKGROUND: </strong>Paracorporeal continuous-flow ventricular assist devices (PCF VAD) are increasingly used in pediatrics, yet PCF VAD resource utilization has not been reported to date.</p>

<p><strong>METHODS: </strong>Pediatric Interagency Registry for Mechanically Assisted Circulatory Support (PediMACS), a national registry of VADs in children, and Pediatric Health Information System (PHIS), an administrative database of children's hospitals, were merged to assess VAD implants from 19 centers between 2012 and 2016. Resource utilization, including hospital and intensive care unit length of stay (LOS), and costs are analyzed for PCF VAD, durable VAD (DVAD), and combined PCF-DVAD support.</p>

<p><strong>RESULTS: </strong>Of 177 children (20% PCF VAD, 14% PCF-DVAD, 66% DVAD), those with PCF VAD or PCF-DVAD are younger (median age 4 [IQR 0-10] years and 3 [IQR 0-9] years, respectively) and more often have congenital heart disease (44%; 28%, respectively) compared to DVAD (11 [IQR 3-17] years; 14% CHD); p &lt; 0.01 for both. Median post-VAD LOS is prolonged ranging from 43 (IQR 15-82) days in PCF VAD to 72 (IQR 55-107) days in PCF-DVAD, with significant hospitalization costs (PCF VAD $450,000 [IQR $210,000-$780,000]; PCF-DVAD $770,000 [IQR $510,000-$1,000,000]). After adjusting for patient-level factors, greater post-VAD hospital costs are associated with LOS, ECMO pre-VAD, greater chronic complex conditions, and major adverse events (p &lt; 0.05 for all). VAD strategy and underlying cardiac disease are not associated with LOS or overall costs, although PCF VAD is associated with higher daily-level costs driven by increased pharmacy, laboratory, imaging, and clinical services costs.</p>

<p><strong>CONCLUSION: </strong>Pediatric PCF VAD resource utilization is staggeringly high with costs primarily driven by pre-implantation patient illness, hospital LOS, and clinical care costs.</p>

DOI

10.1016/j.healun.2021.02.011

Alternate Title

J Heart Lung Transplant

PMID

33744087

Title

Utilization and Outcomes of Children Treated with Direct Thrombin Inhibitors on Paracorporeal Ventricular Assist Device Support.

Year of Publication

2019

Date Published

2019 Nov 20

ISSN Number

1538-943X

Abstract

<p>Thrombotic and bleeding complications have historically been major causes of morbidity and mortality in pediatric ventricular assist device (VAD) support. Standard anticoagulation with unfractionated heparin is fraught with problems related to its heterogeneous biochemical composition and unpredictable pharmacokinetics. We sought to describe the utilization and outcomes in children with paracorporeal VAD support who are treated with direct thrombin inhibitors (DTIs) antithrombosis therapy. Retrospective multicenter review of all pediatric patients (aged &lt;19 years) treated with a DTI (bivalirudin or argatroban) on paracorporeal VAD support, examining bleeding and thrombotic adverse events. From May 2012 to 2018, 43 children (21 females) at 10 centers in North America, median age 9.5 months (0.1-215 months) weighing 8.6 kg (2.8-150 kg), were implanted with paracorporeal VADs and treated with a DTI. Diagnoses included cardiomyopathy 40% (n = 17), congenital heart disease 37% (n = 16; single ventricle n = 5), graft vasculopathy 9% (n = 4), and other 14% (n = 6). First device implanted included Berlin Heart EXCOR 49% (n = 21), paracorporeal continuous flow device 44% (n = 19), and combination of devices in 7% (n = 3). Adverse events on DTI therapy included; major bleeding in 16% (n = 7) (2.6 events per 1,000 patient days of support on DTI), and stroke 12% (n = 5) (1.7 events per 1,000 patient days of support on DTI). Overall survival to transplantation (n = 30) or explantation (n = 8) was 88%. This is the largest multicenter experience of DTI use for anticoagulation therapy in pediatric VAD support. Outcomes are encouraging with lower major bleeding and stroke event rate than that reported in literature using other anticoagulation agents in pediatric VAD support.</p>

DOI

10.1097/MAT.0000000000001093

Alternate Title

ASAIO J.

PMID

31789654

Title

Utilization and Outcomes of Children Treated with Direct Thrombin Inhibitors on Paracorporeal Ventricular Assist Device Support.

Year of Publication

2020

Number of Pages

939-945

Date Published

2020 Aug

ISSN Number

1538-943X

Abstract

Thrombotic and bleeding complications have historically been major causes of morbidity and mortality in pediatric ventricular assist device (VAD) support. Standard anticoagulation with unfractionated heparin is fraught with problems related to its heterogeneous biochemical composition and unpredictable pharmacokinetics. We sought to describe the utilization and outcomes in children with paracorporeal VAD support who are treated with direct thrombin inhibitors (DTIs) antithrombosis therapy. Retrospective multicenter review of all pediatric patients (aged <19 years) treated with a DTI (bivalirudin or argatroban) on paracorporeal VAD support, examining bleeding and thrombotic adverse events. From May 2012 to 2018, 43 children (21 females) at 10 centers in North America, median age 9.5 months (0.1-215 months) weighing 8.6 kg (2.8-150 kg), were implanted with paracorporeal VADs and treated with a DTI. Diagnoses included cardiomyopathy 40% (n = 17), congenital heart disease 37% (n = 16; single ventricle n = 5), graft vasculopathy 9% (n = 4), and other 14% (n = 6). First device implanted included Berlin Heart EXCOR 49% (n = 21), paracorporeal continuous flow device 44% (n = 19), and combination of devices in 7% (n = 3). Adverse events on DTI therapy included; major bleeding in 16% (n = 7) (2.6 events per 1,000 patient days of support on DTI), and stroke 12% (n = 5) (1.7 events per 1,000 patient days of support on DTI). Overall survival to transplantation (n = 30) or explantation (n = 8) was 88%. This is the largest multicenter experience of DTI use for anticoagulation therapy in pediatric VAD support. Outcomes are encouraging with lower major bleeding and stroke event rate than that reported in literature using other anticoagulation agents in pediatric VAD support.

DOI

10.1097/MAT.0000000000001093

Alternate Title

ASAIO J.

PMID

32740356

Title

The impact of pre-implant illness severity on the outcomes of pediatric patients undergoing durable ventricular assist device.

Year of Publication

2020

Date Published

2020 Feb 24

ISSN Number

1557-3117

Abstract

<p><strong>BACKGROUND: </strong>Durable ventricular assist devices (VADs) are increasingly used to treat children with heart failure. Studies demonstrate worse outcomes for those in cardiogenic shock at the time of VAD, but limited data exist on less acutely ill children. We describe the association between illness severity and outcomes in this population.</p>

<p><strong>METHODS: </strong>Data were analyzed from 373 children (aged &lt;19 years) receiving durable VADs from 46 centers in the Pediatric Interagency Registry for Mechanical Circulatory Support. Outcomes were compared by Interagency Registry for Mechanical Circulatory Support (INTERMACS) Patient Profile (PP) and pre-implant characteristics using competing risks methodology.</p>

<p><strong>RESULTS: </strong>Analyses identified 97 patients in cardiogenic shock (PP 1), 222 with progressive decline (PP 2), and 42 stable on inotropes (PP 3). There were 39 infants, 124 were aged 1 to 9 years and 210 were aged 10 to 19 years. A majority had cardiomyopathy and 66 had congenital heart disease (CHD). There were 224 (62%) continuous-flow VADs. Before implant, 40% received mechanical ventilation (MV). Within 6 months post-implant, 57% underwent transplant and 14% died. PP 1 mortality was highest (25% vs 10% for PP 2, hazard ratio [HR]: 2.5, 95% CI: 1.4-4.4, p = 0.02). In PP 1, CHD was an independent mortality risk factor (HR: 2.9, 95% CI: 1.1-7.8, p = 0.03). In PP 2, pulsatile VADs were associated with death (HR: 3.9, 95% CI: 1.6-9.5, p = 0.003). Patients on MV had high mortality (20%-30%) across PP 1 to PP 3 (HR: 3.0 vs no MV, p &lt; 0.001).</p>

<p><strong>CONCLUSIONS: </strong>Children in shock at the time of VAD implant have poor outcomes. MV is associated with increased mortality even in lower acuity INTERMACS profiles. Further study is needed to identify modifiable risk factors in this population.</p>

DOI

10.1016/j.healun.2020.02.011

Alternate Title

J. Heart Lung Transplant.

PMID

32165048

Title

Resource Utilization in Pediatric Patients Supported With Ventricular Assist Devices in the United States: A Multicenter Study From the Pediatric Interagency Registry for Mechanically Assisted Circulatory Support and the PHIS

Year of Publication

2018

Date Published

2018 Jun 01

ISSN Number

2047-9980

Abstract

<p><strong>BACKGROUND: </strong>Few data exist on resource utilization with pediatric ventricular assist devices (VADs). We tested the hypothesis that device type and adverse events are associated with increased resource utilization in pediatric patients supported with VADs.</p>

<p><strong>METHODS AND RESULTS: </strong>The Pediatric Interagency Registry for Mechanically Assisted Circulatory Support, a national registry of VADs in patients &lt;19&nbsp;years old, and the Pediatric Health Information System, an administrative database, were merged. Univariate analysis was performed assessing the association of all factors with the total cost and length of stay first. Significant variables (&lt;0.05) were subjected to multivariable analysis. The study included 142 patients from 19 centers with VAD implants from October 2012 to June 2016. The median age was 9&nbsp;years (interquartile range [IQR] 2-15), 84 (59%) supported with a continuous-flow VAD. Overall median hospital costs were $750&nbsp;000 (IQR $539&nbsp;000 to $1&nbsp;100&nbsp;000) with a median hospital length of stay of 81&nbsp;days (IQR 54-128). On multivariable analysis, device type and postoperative complications were not associated with resource utilization. Factors associated with increased costs included patient age, lower-volume VAD center, being intubated, being on extracorporeal membrane oxygenation, number of complex chronic medical conditions, and length of stay. Among continuous-flow VAD patients, discharge to home before transplant versus remaining hospitalized was associated with lower hospital costs (median $600&nbsp;000 [IQR $400&nbsp;000 to $820&nbsp;000] versus median $680&nbsp;000 [IQR $500&nbsp;000 to $970&nbsp;000], =0.03).</p>

<p><strong>CONCLUSION: </strong>VADs in pediatric patients are associated with high resource utilization. Increased resource utilization was associated with lower-volume VAD centers, disease severity at VAD implantation, and the presence of complex chronic medical conditions. Further study is needed to develop cost-effective strategies in this complex population.</p>

DOI

10.1161/JAHA.117.008380

Alternate Title

J Am Heart Assoc

PMID

29858364

Title

Outcomes of children implanted with ventricular assist devices in the United States: First analysis of the Pediatric Interagency Registry for Mechanical Circulatory Support (PediMACS).

Year of Publication

2016

Number of Pages

578-84

Date Published

2016 May

ISSN Number

1557-3117

Abstract

<p><strong>BACKGROUND: </strong>Use of mechanical circulatory support in children has increased as more options have become available. A national account of the use of mechanical support in children and adolescents is essential to understanding outcomes, refining patient selection and improving quality of care.</p>

<p><strong>METHODS: </strong>The Pediatric Interagency Registry for Mechanical Circulatory Support (PediMACS) is a National Heart, Lung, and Blood Institute-supported nationwide registry for temporary and durable ventricular assist device (VAD) use in patients &lt;19 years of age. Between the launch in September 2012 and June 2015, 37 hospitals in the USA have enrolled patients. This first report of data from PediMACS analyzed pre-implant patient characteristics, survival using competing outcomes, and adverse events.</p>

<p><strong>RESULTS: </strong>Two hundred pediatric patients underwent 222 durable VAD implants. Patients' characteristics and outcomes of children supported with a temporary device (n = 41) were not analyzed in this report. The etiology of heart disease included 146 (73%) patients with cardiomyopathy and 35 (18%) with congenital heart disease. Thirty patients (15%) transitioned from extracorporeal membrane oxygenation (ECMO) and 76 (38%) had previous cardiac surgery. Most patients were Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) Level 1 (27%) or Level 2 (56%) at implant, with 13% at Level 3. Of the 200 patients supported with a durable device, 91 (46%) were supported with a pulsatile-flow device and 109 (55%) with a continuous-flow (CF) device. Patient age at first implant included 30 patients (15%) &lt;1 year of age, 37 (19%) 1 to 5 years, 32 (16%) 6 to 10 years and 101 (51%) 10 to 18 years. Patients were supported with left ventricular assist device alone in 161 (81%), biventricular ventricular assist device in 29 (15%), right ventricular assist device in 4 (2.0%) and total artificial heart in 6 (3%), together comprising 783 months of follow-up. The 200 patients receiving primary durable devices had an actuarial survival of 81% at 6 months. Competing risk analysis at 6 months revealed that 58% of patients had been transplanted, 28% were alive on support, 14% had died and 0.6% recovered. In the overall cohort, there were 28 deaths. Reported serious adverse events included infection (n = 78), bleeding (n = 68), device malfunction (n = 79) and neurologic dysfunction (n = 52).</p>

<p><strong>CONCLUSIONS: </strong>PediMACS constitutes the largest single data repository with detailed information of pediatric patients implanted with VADs. The first PediMACS report reveals favorable outcomes despite the varying patient characteristics and pump types. However, the rate of adverse events remains high. With further data collection, analysis of patient risk factors critical to improving outcomes will be possible.</p>

DOI

10.1016/j.healun.2016.01.1227

Alternate Title

J. Heart Lung Transplant.

PMID

27009673

Title

Outcomes of pediatric patients supported with continuous-flow ventricular assist devices: A report from the Pediatric Interagency Registry for Mechanical Circulatory Support (PediMACS).

Year of Publication

2016

Number of Pages

585-90

Date Published

2016 May

ISSN Number

1557-3117

Abstract

<p><strong>BACKGROUND: </strong>Continuous-flow (CF) ventricular assist devices (VADs) have largely replaced pulsatile-flow VADs in adult patients. However, there are few data on CF VADs among pediatric patients. In this study we aimed to describe the overall use, patients' characteristics and outcomes of CF VADs in this population.</p>

<p><strong>METHODS: </strong>The Pediatric Interagency Registry for Mechanical Circulatory Support (PediMACS) is a national registry for U.S. Food and Drug Adminstration (FDA)-approved VADs in patients &lt;19 years of age. Patients undergoing placement of durable CF VADs between September 2012 and June 2015 were included and outcomes were compared with those of adults from the Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS).</p>

<p><strong>RESULTS: </strong>CF VADs were implanted in 109 patients at 35 hospitals. The median age at implantation was 15 years (2.8 to 18.9 years) and median weight was 62 kg (range 16 to 141 kg). The underlying disease was cardiomyopathy in 89 (82%) patients. The INTERMACS level at time of implant was Level 1 in 20 (19%), Level 2 in 64 (61%) and Levels 3 to 7 in 21 (20%) patients. Most were implanted as LVADs (n = 102, 94%). Median duration of support was 2.3 months (range &lt;1 day to 28 months). Serious adverse event rates were low, including neurologic dysfunction (early event rate 4.1 per 100 patient-months with 2 late events). Competing outcomes analysis at 6 months post-implant indicated 61% transplanted, 31% alive with device in place and 8% death before transplant. These outcomes compared favorably with the 3,894 adults supported with CF VADs as a bridge to transplant.</p>

<p><strong>CONCLUSIONS: </strong>CF VADs are commonly utilized in older children and adolescents, with excellent survival rates. Further study is needed to understand impact of patient and device characteristics on outcomes in pediatric patients.</p>

DOI

10.1016/j.healun.2016.01.1228

Alternate Title

J. Heart Lung Transplant.

PMID

27056612

Title

Second annual Pediatric Interagency Registry for Mechanical Circulatory Support (Pedimacs) report: Pre-implant characteristics and outcomes.

Year of Publication

2018

Number of Pages

38-45

Date Published

2018 Jan

ISSN Number

1557-3117

Abstract

<p><strong>BACKGROUND: </strong>Expanded use of pediatric ventricular assist devices (VADs) has decreased mortality in children awaiting heart transplantation. Pediatric Interagency Registry for Mechanical Circulatory Support (Pedimacs), a National Heart, Lung, and Blood Institute-sponsored North American database, provides a platform to understand this emerging population.</p>

<p><strong>METHODS: </strong>Between September 2012 and September 2016, patients aged younger than 19 years who underwent VAD implantation were enrolled in Pedimacs. FDA approved durable devices as well as temporary support devices were included. The second annual report updates the current Pedimacs data. Patients implanted with temporary devices are included in Pedimacs and this analysis includes this group of paracorporeal continuous flow VADs.</p>

<p><strong>RESULTS: </strong>Over the 4 years, 42 hospitals implanted 432 devices in 364 patients less than 19 yrs of age. Diagnoses included cardiomyopathy in 223 (61%), myocarditis in 41 (11%), and congenital heart disease in 77 (21%), of which 48 had single-ventricle physiology. At implant, 87% were at Intermacs patient profile 1 or 2. The age distribution of children (59% male) supported on VAD included 69 (19%) aged younger than 1 year, 66 (18%) aged 1 to 6 years, 56 (15%) aged 6 to 10 years, and 173 (48%) aged 11 to 19 years. Median follow-up was 2.2 months (range, 1 day to 41.5 months). Median (interquartile) age at implant was 1.7 (0.3-10.0) years for paracorporeal continuous-flow pumps (n = 60), 1.7 (0.4-5.3) years for paracorporeal pulsatile pumps (n = 105), and 15.0 (11.3-16.9) years for implantable continuous-flow pumps (n = 174). Support strategies included LVAD in 293 (80%), biventricular device in 55 (15%), and total artificial heart in 8 (2%). Nearly 50% of patients underwent transplantation within 6 months, with overall mortality of 19%. Adverse event burden continues to be high.</p>

<p><strong>CONCLUSIONS: </strong>Pedimacs constitutes the largest longitudinal pediatric VAD registry. Preimplant data across centers will be helpful at creating shared protocols with which to improve outcomes. Adverse events continue to be the major challenge, especially among the young critically ill children with complex congenital disease.</p>

DOI

10.1016/j.healun.2017.06.017

PMID

28965736

WATCH THIS PAGE