First name
Natalie
Last name
Jayaram

Title

Failure to Rescue as an Outcome Metric for Pediatric and Congenital Cardiac Catheterization Laboratory Programs: Analysis of Data From the IMPACT Registry.

Year of Publication

2019

Number of Pages

e013151

Date Published

2019 Nov 05

ISSN Number

2047-9980

Abstract

<p><strong>Background </strong>Risk-adjusted adverse event (AE) rates have been used to measure the quality of pediatric and congenital cardiac catheterization laboratories. In other settings, failure to rescue (FTR) has demonstrated utility as a quality metric.</p>

<p><strong>Methods and Results </strong>A multicenter retrospective cohort study was performed using data from the IMPACT (Improving Adult and Congenital Treatment) Registry between January 2010 and December 2016. A modified FTR metric was developed for pediatric and congenital cardiac catheterization laboratories and then compared with pooled AEs. The associations between patient- and hospital-level factors and outcomes were evaluated using hierarchical logistic regression models. Hospital risk standardized ratios were then calculated. Rankings of risk standardized ratios for each outcome were compared to determine whether AEs and FTR identified the same high- and low-performing centers. During the study period, 77&nbsp;580 catheterizations were performed at 91 hospitals. Higher annual hospital catheterization volume was associated with lower odds of FTR (odds ratio: 0.68 per 300 cases; =0.0003). No association was seen between catheterization volume and odds of AEs. Odds of AEs were instead associated with patient- and procedure-level factors. There was no correlation between risk standardized ratio ranks for FTR and pooled AEs (=0.46). Hospital ranks by catheterization volume and FTR were associated (=-0.28, =0.01) with the largest volume hospitals having the lowest risk of FTR.</p>

<p><strong>Conclusions</strong> In contrast to AEs, FTR was not strongly associated with patient- and procedure-level factors and was significantly associated with pediatric and congenital cardiac catheterization laboratory volume. Hospital rankings based on FTR and AEs were not significantly correlated. We conclude that FTR is a complementary measure of catheterization laboratory quality and should be included in future research and quality-improvement projects.</p>

DOI

10.1161/JAHA.119.013151

Alternate Title

J Am Heart Assoc

PMID

31619106

Title

Relationship between hospital procedure volume and complications following congenital cardiac catheterization: A report from the IMproving Pediatric and Adult Congenital Treatment (IMPACT) registry.

Year of Publication

2017

Number of Pages

118-128

Date Published

2017 Jan

ISSN Number

1097-6744

Abstract

<p><strong>BACKGROUND: </strong>The association between institutional volume and outcomes has been demonstrated for cardiac catheterization among adults, but less is known about this relationship for patients with congenital heart disease (CHD) undergoing cardiac catheterization.</p>

<p><strong>METHODS: </strong>Within the IMPACT registry, we identified all catheterizations between January 2011 and March 2015. Hierarchical logistic regression, adjusted for patient and procedural characteristics, was used to determine the association between annual catheterization lab volume and occurrence of a major adverse event (MAE).</p>

<p><strong>RESULTS: </strong>Of 56,453 catheterizations at 77 hospitals, an MAE occurred in 1014 (1.8%) of cases. In unadjusted analysis, a MAE occurred in 2.8% (123/4460) of cases at low-volume hospitals (&lt;150 procedures annually), as compared with 1.5% (198/12,787), 2.0% (431/21,391), and 1.5% (262/17,815) of cases at medium- (150-299 annual procedures), high- (300-499 annual procedures), and very-high-volume (≥500 procedures annually) hospitals, respectively, P&lt;.001. After multivariable adjustment, this significant relationship between annual procedure volume and occurrence of an MAE persisted. Compared to low-volume programs, the odds of an MAE was 0.55 (95% CI 0.35-0.86, P=.008), 0.62 (95% CI 0.41-0.95, P=.03), and 0.52 (95% CI 0.31-0.90, P=.02) at medium-, high-, and very-high-volume programs, respectively.</p>

<p><strong>CONCLUSIONS: </strong>Although the risk of MAE after cardiac catheterization in patients with CHD is low at all hospitals, it is higher among hospitals with fewer than 150 cases annually. These results support the notion that centers meeting this threshold volume for congenital cardiac catheterizations may achieve improved patient outcomes.</p>

DOI

10.1016/j.ahj.2016.10.004

Alternate Title

Am. Heart J.

PMID

27979036

WATCH THIS PAGE