First name
Priscila
Middle name
C
Last name
Cevallos

Title

Longitudinal Improvements in Radiation Exposure in Cardiac Catheterization for Congenital Heart Disease: A Prospective Multicenter C3PO-QI Study.

Year of Publication

2020

Number of Pages

e008172

Date Published

2020 May

ISSN Number

1941-7632

Abstract

<p><strong>BACKGROUND: </strong>The C3PO-QI (Congenital Cardiac Catheterization Project on Outcomes - Quality Improvement), a multicenter registry launched in 2015, instituted quality improvement (QI) initiatives to reduce patient radiation exposure. Through regular collaboration, this initiative would allow for harmony among active participants, maximizing efforts and efficiency at achieving radiation best practices. This study sought to report these efforts with a detailed methodology for which institutions can target initiatives, reducing radiation exposure, and increasing patient safety.</p>

<p><strong>METHODS: </strong>Data were collected prospectively by 8 C3PO-QI institutions between January 1, 2015 and December 31, 2017. Radiation exposure was measured in dose area product per body weight (dose area product/kg; µGy*m/kg) and reported by expected radiation exposure categories (REC) and institution for 40 published unique procedure types. Targeted interventions addressing selected strategic domains for radiation reduction were implemented in the pediatric catheterization labs of the C3PO-QI institutions.</p>

<p><strong>RESULTS: </strong>The study consisted of 15 257 unique cases. Median exposure (dose area product/kg) was decreased by 30% for all procedures. Dose area product/kg was reduced in all 3 REC, with the greatest improvement observed in REC I (REC I, -37%; REC II, -23%; REC III, -27%). Although the baseline radiation exposures and exact percent decrease varied across all C3PO-QI sites, each institution demonstrated improvements in radiation dose over time. These improvements occurred with the implementation of institution-specific QI interventions accelerated by participation in the C3PO-QI multicenter collaborative.</p>

<p><strong>CONCLUSIONS: </strong>Substantial radiation dose reductions can be achieved using targeted QI methodology and interventions. Participation in a multicenter QI collaborative may accelerate improvement across all centers due to enhanced engagement and shared learning between sites.</p>

DOI

10.1161/CIRCINTERVENTIONS.119.008172

Alternate Title

Circ Cardiovasc Interv

PMID

32408819
Inner Banner
Publication Image
Inner Banner
Publication Image

Title

Radiation dose benchmarks in pediatric cardiac catheterization: A prospective multi-center C3PO-QI study.

Year of Publication

2017

Number of Pages

269-80

Date Published

2017 Aug 1

ISSN Number

1522-726X

Abstract

<p><strong>OBJECTIVES: </strong>This study sought to update benchmark values to use a quality measure prospectively.</p>

<p><strong>BACKGROUND: </strong>Congenital Cardiac Catheterization Outcomes Project - Quality Improvement (C3PO-QI), a multi-center registry, defined initial radiation dose benchmarks retrospectively across common interventional procedures. These data facilitated a dose metric endorsed by the American College of Cardiology in 2014.</p>

<p><strong>METHODS: </strong>Data was collected prospectively by 9 C3PO-QI institutions with complete case capture between 1/1/2014 and 6/30/2015. Radiation was measured in total air kerma (mGy), dose area product (DAP) (µGy*M(2) ), DAP per body weight, and fluoroscopy time (min), and reported by age group as median, 75(th) and 95(th) %ile for the following six interventional procedures: (1) atrial septal defect closure; (2) aortic valvuloplasty; (3) treatment of coarctation of the aorta; (4) patent ductus arteriosus closure; (5) pulmonary valvuloplasty; and (6) transcatheter pulmonary valve implantation.</p>

<p><strong>RESULTS: </strong>The study was comprised of 1,680 unique cases meeting inclusion criteria. Radiation doses were lowest for pulmonary valvuloplasty (age &lt;1 yrs, median mGy: 59, DAP: 249) and highest in transcatheter pulmonary valve implantation (age &gt;15 yrs, median mGy: 1835, DAP: 17990). DAP/kg standardized outcome measures across weights within an age group and procedure type significantly more than DAP alone. Radiation doses decreased for all procedures compared to those reported previously by both median and median weight-based percentile curves. These differences in radiation exposure were observed without changes in median fluoroscopy time.</p>

<p><strong>CONCLUSIONS: </strong>This study updates previously established benchmarks to reflect QI efforts over time. These thresholds can be applied for quality measurement and comparison. © 2017 Wiley Periodicals, Inc.</p>

DOI

10.1002/ccd.26911

Alternate Title

Catheter Cardiovasc Interv

PMID

28198573
Inner Banner
Publication Image
Inner Banner
Publication Image

Title

Implementation of Methodology for Quality Improvement in Pediatric Cardiac Catheterization: A Multi-center Initiative by the Congenital Cardiac Catheterization Project on Outcomes-Quality Improvement (C3PO-QI).

Year of Publication

2016

Number of Pages

Date Published

2016 Aug 8

ISSN Number

1432-1971

Abstract

<p>The Congenital Cardiac Catheterization Project on Outcomes (C3PO) launched in 2007 as a multi-center collaborative to establish standardized and comparable metrics for pediatric cardiac catheterization procedures. The limitations of larger registries at the time led to the development of the next phase in 2013, C3PO-Quality Improvement (C3PO-QI), focusing on instituting QI initiatives within the field. The objective of this manuscript is to provide a detailed overview of C3PO-QI and report data on case characteristics and outcome metrics being explored. C3PO-QI was designed to cultivate institutional collaboration during implementation of its initiatives. A database and website were developed to support data entry and on-demand reporting. The registry prospectively captures pediatric cardiac catheterization data among 15 hospitals. The present study includes case demographic data (n) and quality metric reporting by case type, age, and radiation dose variables. This dataset includes 13,135 cases entered into the database between 1/1/2014 and 12/31/2015. Interventional cases make up the highest percentage by case mix distribution (48&nbsp;%), and patients &lt;1&nbsp;years make up the highest percentage by age distribution (26&nbsp;%). The ratio of diagnostic and interventional procedures performed changes by age group. Application of QI metric shows all procedure types surpassing metric goals. Large volume data collection, such as in C3PO-QI, allows for meaningful interpretation of data. C3PO-QI is uniquely poised to deliver fast-paced changes in the field. Although the project initiatives are specific to pediatric cardiac catheterization, the implementation of the project and utilization of real-time reporting is generalizable to other specialties and multi-center collaboratives.</p>

DOI

10.1007/s00246-016-1454-z

Alternate Title

Pediatr Cardiol

PMID

27502109
Inner Banner
Publication Image
Inner Banner
Publication Image