First name
Beth
Middle name
D
Last name
Kaufman

Title

Haemodynamic profiles of children with end-stage heart failure.

Year of Publication

2017

Number of Pages

2900-2909

Date Published

2017 Oct 07

ISSN Number

1522-9645

Abstract

<p><strong>Aims: </strong>To evaluate associations between haemodynamic profiles and symptoms, end-organ function and outcome in children listed for heart transplantation.</p>

<p><strong>Methods and results: </strong>Children &lt;18 years listed for heart transplant between 1993 and 2013 with cardiac catheterization data [pulmonary capillary wedge pressure (PCWP), right atrial pressure (RAP), and cardiac index (CI)] in the Pediatric Heart Transplant Study database were included. Outcomes were New York Heart Association (NYHA)/Ross classification, renal and hepatic dysfunction, and death or clinical deterioration while on waitlist. Among 1059 children analysed, median age was 6.9 years and 46% had dilated cardiomyopathy. Overall, 58% had congestion (PCWP &gt;15 mmHg), 28% had severe congestion (PCWP &gt;22 mmHg), and 22% low cardiac output (CI &lt; 2.2 L/min/m2). Twenty-one per cent met the primary outcome of death (9%) or clinical deterioration (12%). In multivariable analysis, worse NYHA/Ross classification was associated with increased PCWP [odds ratio (OR) 1.03, 95% confidence interval (95% CI) 1.01-1.07, P = 0.01], renal dysfunction with increased RAP (OR 1.04, 95% CI 1.01-1.08, P = 0.007), and hepatic dysfunction with both increased PCWP (OR 1.03, 95% CI 1.01-1.06, P &lt; 0.001) and increased RAP (OR 1.09, 95% CI 1.06-1.12, P &lt; 0.001). There were no associations with low output. Death or clinical deterioration was associated with severe congestion (OR 1.6, 95% CI 1.2-2.2, P = 0.002), but not with CI alone. However, children with both low output and severe congestion were at highest risk (OR 1.9, 95% CI 1.1-3.5, P = 0.03).</p>

<p><strong>Conclusion: </strong>Congestion is more common than low cardiac output in children with end-stage heart failure and correlates with NYHA/Ross classification and end-organ dysfunction. Children with both congestion and low output have the highest risk of death or clinical deterioration.</p>

DOI

10.1093/eurheartj/ehx456

Alternate Title

Eur. Heart J.

PMID

29019615

Title

The Use of Pediatric Ventricular Assist Devices in Children's Hospitals From 2000 to 2010: Morbidity, Mortality, and Hospital Charges.

Year of Publication

2015

Number of Pages

522-8

Date Published

2015 Jul

ISSN Number

1529-7535

Abstract

<p><strong>OBJECTIVE: </strong>The use of ventricular assist devices has increased dramatically in adult heart failure patients. However, the overall use, outcome, comorbidities, and resource utilization of ventricular assist devices in pediatric patients have not been well described. We sought to demonstrate that the use of ventricular assist devices in pediatric patients has increased over time and that mortality has decreased.</p>

<p><strong>DESIGN: </strong>A retrospective study of the Pediatric Health Information System database was performed for patients 20 years old or younger undergoing ventricular assist device placement from 2000 to 2010.</p>

<p><strong>INTERVENTIONS: </strong>None.</p>

<p><strong>MEASUREMENTS AND MAIN RESULTS: </strong>Four hundred seventy-five pediatric patients were implanted with ventricular assist devices during the study period: 69 in 2000-2003 (era 1), 135 in 2004-2006 (era 2), and 271 in 2007-2010 (era 3). Median age at ventricular assist device implantation was 6.0 years (interquartile range, 0.5-13.8), and the proportion of children who were 1-12 years old increased from 29% in era 1 to 47% in era 3 (p = 0.002). The majority of patients had a diagnosis of cardiomyopathy; this increased from 52% in era 1 to 72% in era 3 (p = 0.003). Comorbidities included arrhythmias (48%), pulmonary hypertension (16%), acute renal failure (34%), cerebrovascular disease (28%), and sepsis/systemic inflammatory response syndrome (34%). Two hundred forty-seven patients (52%) underwent heart transplantation and 327 (69%) survived to hospital discharge. Hospital mortality decreased from 42% in era 1 to 25% in era 3 (p = 0.004). Median hospital length of stay increased (37 d [interquartile range, 12-64 d] in era 1 vs 69 d [interquartile range, 35-130] in era 3; p &lt; 0.001) and median adjusted hospital charges increased ($630,630 [interquartile range, $227,052-$853,318] in era 1 vs $1,577,983 [interquartile range, $874,463-$2,280,435] in era 3; p &lt; 0.001). Factors associated with increased mortality include age less than 1 year (odds ratio, 2.04; 95% CI, 1.01-3.83), acute renal failure (odds ratio, 2.1; 95% CI, 1.26-3.65), cerebrovascular disease (odds ratio, 2.1; 95% CI, 1.25-3.62), and extracorporeal membrane oxygenation (odds ratio, 3.16; 95% CI, 1.79-5.60). Ventricular assist device placement in era 3 (odds ratio, 0.3; 95% CI, 0.15-0.57) and a diagnosis of cardiomyopathy (odds ratio, 0.5; 95% CI, 0.32-0.84), were associated with decreased mortality. Large-volume centers had lower mortality (odds ratio, 0.55; 95% CI, 0.34-0.88), lower use of extracorporeal membrane oxygenation, and higher charges.</p>

<p><strong>CONCLUSIONS: </strong>The use of ventricular assist devices and survival after ventricular assist device placement in pediatric patients have increased over time, with a concomitant increase in resource utilization. Age under 1 year, certain noncardiac morbidities, and the use of extracorporeal membrane oxygenation are associated with worse outcomes. Lower mortality was seen at larger volume ventricular assist device centers.</p>

DOI

10.1097/PCC.0000000000000401

Alternate Title

Pediatr Crit Care Med

PMID

25850863